ASHUTOSH RANE
Member level 2
How to calculate Slew Rate for Differential folded cascode opamp.in cadence can anybody tell me ....??
thanks in advance...:smile:
thanks in advance...:smile:
Follow along with the video below to see how to install our site as a web app on your home screen.
Note: This feature may not be available in some browsers.
SR+ =229e6.
SR- =-227e6
CL=1pF
but these are very high values right ....??
have i done any mistake in calculation of maximum slope??