Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

About Assura QRC in IBM cms9flp

Status
Not open for further replies.

shahriar22nd

Member level 2
Member level 2
Joined
Sep 24, 2009
Messages
45
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,286
Location
Dhaka, Bangladesh
Activity points
1,663
Hello all,
I am trying to extract the layout of an inverter in IBM cms9flp, with Assura 3.1.7, Cadence IC6.1.2. But I do not see any option for Assura QRC/RCX in the IBM_PDK pull down menu of the Layout Editor Window, like Assura DRC/LVS. I found 'Assura -> Run RCX' which is another pull down menu in that window, but no option for Assura QRC !
Could anyone please write me whether I need EXT installed for this option? I did not install the IC and I think I do not have EXT running in my machine, because I did not see any path for it in my .cshrc file. Is EXT obvious for Assura RCX, too?
Thank you
 

Refer here: . You probably need Assura3.2 now, refer to the release notes for the assura kit. In Assura3.2 the assura pulldown menu will have Run QRC
 
Thank you oermens for your reply. It was very helpful.
In , you mentioned that, path for EXT must come before that of Assura. does it mean that, I shall need EXT together with the Assura 3.2? Is EXT essential for both Assura QRC and RCX?
 

When EXT comes before ASSURA in PATH, QRC overrides RCX. Note that extraction is not done from the IBM_PDK menu. Once you complete successful LVS (does not have to match, just complete without error), Assura>Run QRC will be available.

Update your IC to 613 also, 612 is very old. There is 614 but not supported by IBM yet. Always refer to release notes from the kit for what versions of the tools are required.
 
I've got a similar problem but I'm not sure how to fix it.
I'm using Cadence 6.1 and working with Assura 4.1. I've just got EXT 9.1 installed as well but after launching RCX the run fails with the following warnings:

*WARNING* No library model for device "N_PG52P5_LLHVT".
*WARNING* No library model for device "N_PG52P5_LLHVT".
*WARNING* No library model for device "N_PD52P5_LLHVT".
*WARNING* No library model for device "N_PD52P5_LLHVT".
*WARNING* No library model for device "P_L52P5_LLHVT".
*WARNING* No library model for device "N_PG97P4_LLHVT".
*WARNING* No library model for device "N_PG97P4_LLHVT".
*WARNING* No library model for device "N_PD97P4_LLHVT".
*WARNING* No library model for device "N_PD97P4_LLHVT".
*WARNING* No library model for device "P_L97P4_LLHVT".
*WARNING* No library model for device "N_PG144P5CAM_LLHVT".
*WARNING* No library model for device "N_PG144P5CAM_LLHVT".
*WARNING* No library model for device "N_PD144P5CAM_LLHVT".
*WARNING* No library model for device "N_PD144P5CAM_LLHVT".
*WARNING* No library model for device "N_CPD144P5CAM_LLHVT".
*WARNING* No library model for device "N_CPD144P5CAM_LLHVT".
*WARNING* No library model for device "P_L144P5CAM_LLHVT".
*WARNING* No library model for device "RSNPO_EFUSE".
*WARNING* No library model for device "RSPPO_EFUSE".
*WARNING* No library model for device "RAL".
*WARNING* No library model for device "DION_LL_A".
*WARNING* No library model for device "DION_LL_A".
*WARNING* No library model for device "DIOP_LL_A".
*WARNING* No library model for device "L_SLCR30K_RFVIL ivpcell".
*WARNING* No library model for device "L_SYCT30K_RFVIL ivpcell".
*WARNING* No library model for device "L_SY30K_RFVIL ivpcell".
*WARNING* No library model for device "L_SQSK_RFVIL ivpcell".

Finished /tools/CDS/ASSURA_4.1OA/tools/assura/bin/rcxToDfII
Constructing the RCX run script
Could not open file /home/marino/prova3/Assura/LVS/RCXspiceINIT for reading
*WARNING* Bad return status from RCX script generator. 0x100




Moreover, in the LOG I see the following:




Assura RCX Run: Loading Technology Data. Standby...
INFO no run detected for cell NOT_10 layout 4DMPET
INFO no run detected for cell NOT_10 layout 4DMPET
INFO no run detected for cell NOT_10 layout 4DMPET
INFO no run detected for cell NOT_10 layout 4DMPET
INFO no run detected for cell NOT_10 layout 4DMPET
INFO no run detected for cell NOT_10 layout 4DMPET
INFO no run detected for cell NOT_10 layout 4DMPET
*WARNING* hiCreateCyclicField: value must be within the choice list. Setting to first choice.
*WARNING* hiCreateCyclicField: value must be within the choice list. Setting to first choice.

Loading tech rule set file : /home/marino/prova3/Assura/LVS/techRuleSets
Rule file does not contain switches: TOP_METAL_THICKNESS_30K .
So these switches are considered as unused and removed from the field "Switch Names" of "Run Assura LVS" form.

Loading tech rule set file : /home/marino/prova3/Assura/LVS/techRuleSets

Loading tech rule set file : /home/marino/prova3/Assura/LVS/techRuleSets

Loading tech rule set file : /home/marino/prova3/Assura/LVS/techRuleSets
display full path...
Assura LVS: State loaded "Last"
*INFO*: Checking whether schematic is up to date.
*INFO*: Schematic integrity check is completed.
Assura LVS: State saved "Last"
Host is
cmd is /tools/CDS/ASSURA_4.1OA/tools/assura/bin/assura /home/marino/prova3/LVS_RunFiles/NOT_10.rsf -cdslib /home/marino/prova3/cds.lib -gui
Starting the Assura LVS Run: IPC Id ipc:2: pid 6918.
Tailing "/home/marino/prova3/LVS_RunFiles/NOT_10.log"
STATUS: Schematic and Layout Match

Checking out license for "Assura_UI" 4.10
Schematic cell - NOT_10 schematic 4DMPET
FILE : /home/marino/prova3/LVS_RunFiles/NOT_10.cel EMPTY
Schematic cell - NOT_10 schematic 4DMPET
Unable to determine the schematic hierarchy path.
Opening the schematic top cell for the layout cell("/")
Assura RCX Run: Loading Technology Data. Standby...
*WARNING* Current technology is "umc65ll_LVS", but .tpl file was not loaded for some reasons.

Loading tech rule set file : /home/marino/prova3/Assura/LVS/techRuleSets
*Info* Default Substrate Tech Dir is not defined, replaced with the empty name
*WARNING* Current technology is "umc65ll_LVS", but .tpl file was not loaded for some reasons.
Warning: SNA Tech Dir is not a directory, trying the default SNA Tech Dir
Warning: Default SNA Tech Dir is not a directory, replaced with the current directory
*Info* Ignoring overWriteRuleSets from the State File
*Info* Ignoring selectedRuleSets from the State File
*Info* Ignoring selectedDirs from the State File
*Info* Ignoring rcxNets from the State File
*Info* Ignoring rcxNetsFromFile from the State File
*Info* Ignoring rcxNetsFile from the State File
*Info* Ignoring rcxFSNets from the State File
*Info* Ignoring rcxFSNetsFromFile from the State File
*Info* Ignoring rcxFSNetsFile from the State File
*Info* Ignoring fixedNets from the State File
*Info* Ignoring fixedNetsFromFile from the State File
*Info* Ignoring fixedNetsFile from the State File
*Info* Ignoring inductanceNets from the State File
*Info* Ignoring inductanceNetsFromFile from the State File
*Info* Ignoring inductanceNetsFile from the State File
*Info* Ignoring substrateNets from the State File
*Info* Ignoring substrateNetsFromFile from the State File
*Info* Ignoring substrateNetsFile from the State File
*Info* Ignoring resistanceMesh from the State File
*Info* Ignoring resistanceMeshBool from the State File
Load complete.
*WARNING* Cell View Exists. Overwrite?

Library: 4DMPET
Cell: NOT_10
View: av_extracted
Host is
RsfFile is /home/marino/prova3/LVS_RunFiles/rcx.NOT_10.rsf
LogFile is /home/marino/prova3/LVS_RunFiles/rcx.NOT_10.log
cmd is /tools/CDS/ASSURA_4.1OA/tools/assura/bin/assura /home/marino/prova3/LVS_RunFiles/rcx.NOT_10.rsf -cdslib /home/marino/prova3/cds.lib
Starting the ipc:2 Run: IPC Id 8240: pid "Assura RCX".
Tailing "/home/marino/prova3/LVS_RunFiles/rcx.NOT_10.log"
*Error* The Assura RCX run "NOT_10" failed!
The log File is at: /home/marino/prova3/LVS_RunFiles/rcx.NOT_10.log


Actually I use set_tool when I log in my unix environment so I first install EXT and afterwards Assura so I think that's equivalent in having EXT before Assura in PATH. Is that correct?? Notwithstanding I can see only the RCX menu but not the QRC one...
I also had to follow some steps in order to create the unified qrcTechFile but I am not sure I did it right. I'm really getting crazy with this stuff!!! Please, help!!!! :|
 
Last edited:

maybe there's some mistake in your environment setting, So you can't invoke QRC instead of RCX, here is how i fix it. Hope it could help you.
export QRC_HOME=/home/akon/cadence/EXT91
export QRC_ENABLE_EXTRACTION="t"
export ASSURAHOME=/home/akon/cadence/ASSURA4
export PATH=$QRC_HOME/bin:$QRC_HOME/tools/bin:$ASSURAHOME/bin:$ASSURAHOME/tools.lnx86/bin:$PATH
 
Thank you akon_cn,
I fixed the problem in a similar way...
 