Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

For which signal we need to do Sheilding....?

Status
Not open for further replies.

Sidramareddy

Junior Member level 3
Junior Member level 3
Joined
May 31, 2011
Messages
28
Helped
7
Reputation
14
Reaction score
6
Trophy points
1,283
Location
Bangalore, India
Activity points
1,418
If there are two signals like Vref n Ibias in a single layout...then which signal we need to sheild....?
 

In this particular case I would select to shield the voltage more than the current. But, why not shield them both?

Also, from the naming convention they seem to be static signals and you should therefore shield them at places where they cross HF wires or other AC wires/nodes. As such, due to their static nature, you do not have to consider any impedance matching (i.e., full ground shield).
 