Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

DC bias to a device, and measuring the S11 with a VNA... will this damage the VNA?

Status
Not open for further replies.

lab-lab

Newbie level 6
Newbie level 6
Joined
Feb 9, 2011
Messages
12
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,364
Good morning,

I have to perform some measurements through a VNA. However, I have to bias the diode that is in the device under test. The polarization bias is very low (0.7V)...however, I'm afraid that I can damage the instrument ...
Should I use anything to block the DC from going into VNA!?

May it help if I gave you the model of the VNA I'm using?
Thanks!
 

Hello,

Please take a look into your VNA's spec or user guide. Generaly it contains dc blocking capacitor (my E5071C - up to 35V), but it will be better to check. Also you can use external DC Block, but you must recalibrate your VNA to remove added amp/phase uncertainty.
 
Thanks for the answer... my VNA is the R&S ZVL-6. I really can't find the answer in the specifications. May you check if it has some built-in capabilities that preserve it when performing measurements with an external bias? The DC blocking capacitor is usually inside the VNA or external?
Thanks
 

At most instruments, also ZVL series, there's a text about maximum ratings beneath the test ports that answers your question.
 
As a matter of fact, there is written "MAX +27dBm/ 30V DC"....... so it shoudl actually refer to a possible external "in-going signal" that may wonder through the device under test?
 

So, what's the use of th so-called power probe!?
 

Hello lab-lab

I am using too a VNA ZVR and to have no problem you can use an external DC block from Huber+Suhner 10-5Ghz/250V.Also , i have maked another calibration (it is necesary).Hope you will success.

Regards
 