Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

How can I creat new result in CST?

Status
Not open for further replies.

salma

Junior Member level 2
Junior Member level 2
Joined
Dec 6, 2007
Messages
24
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,461
Hi

How can I creat new result in CST? for example, I want to know subtraction of two results, for example |S11|-|S22|, are there any ways to define this new parameters? in HFSS, I do this using output variables.

Regards
 

Hi
You can find it in Results>Template Based Processing>Mix 1d results.
Regards
 
  • Like
Reactions: salma

    salma

    Points: 2
    Helpful Answer Positive Rating
dear myazdi83

Thank you very much, but this message is appeared, " No 1d results template exists, Mix 1d not possible".
Do I have to do something before simulation?
 

yes.
you should first define your parameters which are contanied in the equation.
for example first define magnitude of S11 from Results>Template Based Processing>s-parameters. Then you should define magnitude of S22. then,You can find it in Results>Template Based Processing>Mix 1d results.
regards
 
If my results are not exist in the list, for example I need some processing in the E-field of probe, what do I do?

Thank you
 

could you write your complete desired equation.
 
  • Like
Reactions: salma

    salma

    Points: 2
    Helpful Answer Positive Rating
ok,

A linearly polarized field (E field in the x direction) is incident on my structure.My structure is chiral and it rotates the polarization of the incident wave. I want to calculate the transmission coefficient for the right circular polarized and left circular polarized.So, on the other side of the structure, I measure the transmitted E-field in the x and y direction using probes.
Now, I must calculate Ex+iEy and Ex-iEy. what do you suggest?

regards
 

ok.
Have you seen this example of CST?
file:///C:/Program%20Files/CST%20STUDIO%20SUITE%202010/Online%20Help/mergedProjects/Examples_Overview_MWS/examplesoverview/fss__simulation_of_resonator_array.htm
and Is your problem like this?
It would be usefull.
 
  • Like
Reactions: salma

    salma

    Points: 2
    Helpful Answer Positive Rating
yes,

My simulation is slightly different. In that example, the incident plane wave angle is varied and effect of its on s_parameter is plotted. But, in my simulation ,the incident plane wave angle is normal and I need to calculate rotation of polarization versus frequency:(

Anyway, thanks for your help.
 

ok.
If you excite the port with only 1 mode (suppose vertically oriented) then the s21(1,2) shows the amount of mode 1 that convert to the horizontal mode. (am i right?)
but if it dont satisfies your desired result, i suggest that export your result data from CST and import them to the MATLAB and do everything you want with them!!!
Regards
 
  • Like
Reactions: salma

    salma

    Points: 2
    Helpful Answer Positive Rating
@ myazdi83
how one can import data to CST from matlab??? do you have any idea
many thanks
 

@ myazdi83
how one can import data to CST from matlab??? do you have any idea
many thanks

from Navigation Tree>1D results>(Right clik)>Import Results Curves From ASCII files
be happy
 

@myazdi83
i am sorry but i cant find Import Results Curves From ASCII files ????


Many thanks
 

@myazdi83
i am sorry but i cant find Import Results Curves From ASCII files ????


Many thanks

OK, first create a New Folder and then do it, like this:


https://obrazki.elektroda.pl/48_1329053013.jpg
https://obrazki.elektroda.pl/21_1329053013.jpg

---------- Post added at 14:24 ---------- Previous post was at 14:24 ----------

@myazdi83
i am sorry but i cant find Import Results Curves From ASCII files ????


Many thanks

OK, first create a New Folder and then do it, like this:


https://obrazki.elektroda.pl/48_1329053013.jpg
https://obrazki.elektroda.pl/21_1329053013.jpg
 
@myazdi83
how can we update CST parameter via VBA ? and can run the T-solver with the updated parameters ?
Regards...
 

@myazdi83
how can we update CST parameter via VBA ? and can run the T-solver with the updated parameters ?
Regards...

If the defined parameters are global, they will be updated when you define a parameter sweep in T-solver.
Regards.
 

hello
when i asked about importing information to CST i meant that i want to change the parameters from MATLAB ??
 

If the defined parameters are global, they will be updated when you define a parameter sweep in T-solver.
Regards.
but they are global already ... do you know a VBA code to update the parameters and run T-Solver with the new parameters
i try to start the T-Solver after making parameter sweep by this code
Solver.Start
Save
but it get the result from the old parameters (i.e before parameter sweep)
thank you ..
Regards...
 

hi everybody
i have a problem with cst output file
when i run my script code with FDsolver(i use floquetprot & unit cell) i got some result like " %SZmax(1),Zmax(1)% versus Passes in dB.tab".
i want link cst & MATLAB then it should be txt file. CST'output should be .sig file to have ASCII outpot then i got error and i cant get outpot in txt file.i should do it with vba code. pleaaaaaaaaaaaase help me:( its emergency
 