Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Parametric Sweep in CST MWS

Status
Not open for further replies.

ahsaan

Member level 5
Member level 5
Joined
Apr 25, 2009
Messages
81
Helped
13
Reputation
26
Reaction score
11
Trophy points
1,288
Location
Pakistan
Activity points
1,681
Hello
My results of Parametric sweep are not saving....I have run Par. sweep from transient solver but the results are not being saved...
 

hello ahsaan,
go to transient solver >> and tick store results data in cache.

once simulation is over goto the simulation folder (should be same name as your CST file name) >> Result >> Cache >>and then you can see different folders with RUN 00XX.

Each folder got a seperate file for a parameter.

Hope it helps ..

Regards

Praful
 

    V

    Points: 2
    Helpful Answer Positive Rating
hi,

U should use MACRO - WIZARD - COMPARE MULTIPLE RUNS,
but be sure - as the other user posted - that you have stored
before all runs in cache, this is an option of the solver dialog
box.
 

    V

    Points: 2
    Helpful Answer Positive Rating
Status
Not open for further replies.

Similar threads

Part and Inventory Search

Welcome to EDABoard.com

Sponsor

Back
Top