Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

How to select farfield component for optimsation?

Status
Not open for further replies.

Element7k

Advanced Member level 1
Advanced Member level 1
Joined
May 7, 2003
Messages
434
Helped
26
Reputation
52
Reaction score
19
Trophy points
1,298
Location
TherealLapland
Visit site
Activity points
4,278
Dear all,

I will like to optimise the farfield pattern of an antenna for max gain e.g. in the theta component. I use the user defined function in the optimiser but I do not know how to select the field component. E.g. I wish to look at Farfield\farfield (f=x) [1] but I do not know how select e.g. theta/axial ratio in VBA to optimise. Can anyone help to modify the code given in CST example to select e.g. the Phi component.

Thanks in advance.

Function GoalFunction() As Double

Dim cst_value As Double
With FarfieldPlot
.Reset
SelectTreeItem "Farfields\farfield (f=1.25) [1]"
.SetPlotMode "gain"
.SetScaleLinear False
.Plottype "polar"
.Vary "theta"
.Thetastep 1
.Phi 0
.Plot
Wait 0.02
' Maximize gain
GoalFunction=10/Abs(.Getmax)

End With

End Function
 

Hi!

instead of writing your own goal function, you simply could use a "Result Template". In these templates, you can directly select any Far field component you like an you can directly use the results in the optimiser, too!

I just checked, the Thta Gain Max valu is directly available under 0D Template -> Farfield...

F.
 