fala
Full Member level 5
Hello, I use protel DXP 2004 build 8.0.4.1272. For grouping nets in net classes I used to assign net labels to nets in schematic and then I would go to PCB and in Design>Classes I would arrange thoes net labels as classes to assign rules between them until today that I read an interesting post in this forum that suggests life is even more comfortable than I would imagine.
Thank you very much.
but my happiness did not last for too long when I found out that in my protel DXP 2004 in Place>Directives there is no net classes. I have only No ERC, Probe, Test Vector Index, Stimulus, PCB Layout and parameter set. and also in Project>Project Options, I do not have Class generation. So dose it mean that I have to accept life as it used to be? Is there any way that I can group nets in schematics in net classes?House_Cat said:To add your class on the schematic, go to the page for the nets that you have in your class. Select Place>Directives>Net Class. Hit 'Tab' when the 'net class' label is floating on the cursor, and enter your information. Now attach the class to the wire(s) for your net class.
You can also set up your net class by going to Project>Project Options>Class Generation. Check the box at the bottom of the page in the section "User-Defined Classes". Read the information that pops up when the box is checked.