Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

How to obtain bulk conductivity having surface resistivity?

Status
Not open for further replies.

rola24

Newbie level 4
Newbie level 4
Joined
Jan 21, 2006
Messages
6
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,316
If I have a surface resistivity (ohm/square) how i can obtain the bulk conductivity of the material?
 

surface resistivity bulk conductivity

Hi Rola24!

In order to get the Conducting value of the material you need to convert the Resistance value from [Ω/m²] to [S/m]

First you need to refer to it as a length [m] and not as area [m²] then all you have to do is to inverse the value to get the Conductance:

Cond. = 1 / Resist.

and in physical units:

Simens = 1/Ohm (S = 1/Ω)


Bye,

Itzik

P.S.
You can leave the units of the area as they are - in this case you will have the Conductance of an area (instead of a lenght - the S/m is more popular in applied physics)
 

surface resistivity paper volume

Hi

In the paper they Rs= 100Ω/square. And in the HFSS simulation they put that the bulk conductivity is 277 siemens/m but i didnt understand from where this number come?
 

surface resistivity value

Hi !

I think its because they using a closed cubic of 36.1 micron³ in volume for the simulation.

If you divide the Resistive with the bulk Conductance you get 36.1e-6 m³.
So by making a division of Resistive value with the volume value, you get a bulk conductivity of 277 S/m.


Itzik
 

    rola24

    Points: 2
    Helpful Answer Positive Rating
ohm/square to siemens/m

how I can check if the closed cubic is 36.1 micron³ in the HFSS. and if I want to simlulate the antenna in SEMCAD. I should also use 277s/m ?
 

convert conductivity s/m to resistivity ohm/sq

Hi Rola24 !

I don't really in the HFSS sim. soft. but as far as i can know you really have tools for measuring the volume of any given object in it. (Unlike CST which have some limited ways for measuring length by Picking Faces Tool).

Secondly, I don't know SEMCAD but if it 3D sim. soft. you should use the same value; 277 S/m

Good luck !

Itzik
 

    rola24

    Points: 2
    Helpful Answer Positive Rating