Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

LCD engineering units

Status
Not open for further replies.

calamar

Newbie level 3
Newbie level 3
Joined
Sep 21, 2005
Messages
3
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,318
lcd 4094

Someone Know LCD with engineering units ?, without
controller I need it for baettery powered, I'm tring to
desing a flow rate, I found a few manufacters of custom
LCD but I could't get a clue about LCD manufacturer dedicate to
LCD for insturmentacion.

Best Regards
 

lcd engineering

how many pieces do you need?
 

    calamar

    Points: 2
    Helpful Answer Positive Rating
od-407 datasheet

I am looking for LCD operated @ 3.3v
 

display lcd od 407

u have placed a ambiguous question make it clear
it doesnt have clarity in it
plz make it clear
 

what are engineering units

Kasd:
I need 25 pieces to start, after that
50 pieces(approach) every 90 days,

Syed:
I am looking for LCD manufactures
that can offer something like to this:

> 6 to 8 Digits in line (approach .3" to .5" font size)
> in a small font size beside, below or above the units:
* Sg/Mn/Hs
* Lt/Gl/M3

The above description is just a example,
many LCD with engineering units could be
ok,
 


    calamar

    Points: 2
    Helpful Answer Positive Rating
display lcd 4 digit 4094

Thank Kasd, but these LCD aren't suitable
to battery powered, the current comsumption
should be less than 50uA

I was reading hitachi 44780 datasheet and it
current consumption is to much to develope
a low-power LCD module, there is a LCD module
with another controller to use in a very low powerd
system ?
 

od407

calamar said:
Thank Kasd, but these LCD aren't suitable
to battery powered, the current comsumption
should be less than 50uA

I was reading hitachi 44780 datasheet and it
current consumption is to much to develope
a low-power LCD module, there is a LCD module
with another controller to use in a very low powerd
system ?
Hi, why not try with shift registers 4094 ? I was make a 4 digit LCD dual channel termometer and humidity meter with PIC18F252 & 4094. For LCD control are used four 4094, and 4 pins of PIC18F252. Current consumption from four 4094 is approximately 10-15 uA. Refresh rate is 64 Hz. LCD display is OD-407 ( 4 digit 12.70mm height LCD ) from Comet Electronics, www.comet.bg .
You can use SPI channel to load data in shift registres or can load them with software. After loading data to LCD, I am put PIC18F252 in sleep mode and total consumption is ~300uA.
 

lcd 4094

Hi calamar,

Is the LCD link provided by pirev is able to fit your requirements?

kasd
 