mediative
Member level 1
how to get power anaylsis with io pads
after doing the power analysis , I get the report file.
but the power is so small, I can't believe it . so I check my IO timing libray, I found that the timing is not defined for cell corner、power and ground. Is this the crucial reason?
##############################################
# The Power Analysis Report for VDD net #
##############################################
power supply: 1.62 v
average power(default): 4.0356e-03 mw
average switching power(default): 0.0000e+00 mw
average internal power(default): 0.0000e+00 mw
average leakage power(default): 4.0356e-03 mw
average user specified power(default): 0.0000e+00 mw
average power by clock domain category:
unclock domain: 4.0356e-03 mw
average power by cell category:
core: 4.0356e-03 mw
block: 0.0000e+00 mw
io: 0.0000e+00 mw
average power(considered in rail analysis): 2.0074e-03 mw
worst IR drop average analysis: 7.9231e-07 v
number of nodes in rail network: 27564 nodes
worst EM:
"M1" 2.9630e-05 mA/u
"M2" 9.0687e-06 mA/u
"M3" 1.1908e-04 mA/u
"M4" 7.8897e-06 mA/u
"M5" 2.8015e-05 mA/u
"M6" 3.2509e-05 mA/u
"V23" 7.2550e-06 mA/cut
"V34" 4.0366e-06 mA/cut
"V45" 4.0366e-06 mA/cut
"V56" 5.3821e-06 mA/cut
after doing the power analysis , I get the report file.
but the power is so small, I can't believe it . so I check my IO timing libray, I found that the timing is not defined for cell corner、power and ground. Is this the crucial reason?
##############################################
# The Power Analysis Report for VDD net #
##############################################
power supply: 1.62 v
average power(default): 4.0356e-03 mw
average switching power(default): 0.0000e+00 mw
average internal power(default): 0.0000e+00 mw
average leakage power(default): 4.0356e-03 mw
average user specified power(default): 0.0000e+00 mw
average power by clock domain category:
unclock domain: 4.0356e-03 mw
average power by cell category:
core: 4.0356e-03 mw
block: 0.0000e+00 mw
io: 0.0000e+00 mw
average power(considered in rail analysis): 2.0074e-03 mw
worst IR drop average analysis: 7.9231e-07 v
number of nodes in rail network: 27564 nodes
worst EM:
"M1" 2.9630e-05 mA/u
"M2" 9.0687e-06 mA/u
"M3" 1.1908e-04 mA/u
"M4" 7.8897e-06 mA/u
"M5" 2.8015e-05 mA/u
"M6" 3.2509e-05 mA/u
"V23" 7.2550e-06 mA/cut
"V34" 4.0366e-06 mA/cut
"V45" 4.0366e-06 mA/cut
"V56" 5.3821e-06 mA/cut