Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

MOS resistor switch for controlling capacitor

Status
Not open for further replies.

Junus2012

Advanced Member level 5
Advanced Member level 5
Joined
Jan 9, 2012
Messages
1,552
Helped
47
Reputation
98
Reaction score
53
Trophy points
1,328
Location
Italy
Activity points
15,235
Hello,

I am using MOS switch for controlling bank of capacitors.

The capacitor bank is a binary weighted array start from 50 fF, 100fF, 200 fF, 400 fF, 80 fF, 1.6 pF,

These capacitor represent the compensation capacitor for my op-amp toward bulding programmable bandwidth amplifier.

Coming to the switch size, what is the rule for sizing it?

I have read that ratio should be high enough to achieve the current phase of a capacitor in the range of -90 ° plus minus 1°, is that true? and how can I simulate it?

this means for every capacitor value there must be different size switch depending on the controlled capacitor size

Thank you in advance for your help

Regards
 

You can run the AC analysis simulation in P-SPICE. This will calculate the frequency response of the circuit. This will allow you to observe the phase shift of the current through the capacitor bank. During the simulation process, you can vary the dimensions of the MOS switch, such as the width-to-length ratio (W/L), to determine its optimal size.
 