Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

can secondary inductance be determined from provided data

Status
Not open for further replies.

Zak28

Advanced Member level 2
Advanced Member level 2
Joined
Aug 19, 2016
Messages
579
Helped
6
Reputation
12
Reaction score
6
Trophy points
18
Activity points
4,681
Recently obtained this for its great peak current handling but nothing about secondary inductance.

https://www.summitracing.com/parts/pnx-d3070

Code:
Primary Resistance: 0.350 ohms
Secondary Resistance: 8.30K ohms
Inductance (Primary): 2.80 mH
Turns Ratio: 85:1
Peak Current: 7.9 amps
Spark Duration: 1.5 mS

Going to determine its parasitic capacitance with ordinary phase relations for yielding some accuracy to simulation with this transformer. However not sure whether supplied data is sufficient for secondary inductance. Perhaps an estimate can be given since its value isn't likely in range of LCR meter it being too large to measure.
 
Last edited:

Available data is enough to calculate secondary inductance

Primary inductance: 2.8mH
Turns ratio: 85:1
Consider Primary 1 turns and Secondary 85 turns
AL Value : 2.8mH/1^2=2.8mH
Secondary inductance : 2.8*85^2 =20230mH

Hope it will help you
 
Secondary has an enormous reactance to its rated 1.5mS period yielding ~4190R.

However is that impedance only applicable to sustained oscillations or is impulse current at its rated period also impeded?
 

Really you should describe the turns ratio as 1:85 i.e. pri to sec ... the sec L is the turns ratio squared times the pri L
 