Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

[SOLVED] Are there relays made for inductive loads

Status
Not open for further replies.

Zak28

Advanced Member level 2
Advanced Member level 2
Joined
Aug 19, 2016
Messages
579
Helped
6
Reputation
12
Reaction score
6
Trophy points
18
Activity points
4,681
Are they relays which are made to drive inductive loads and can subsittute a low side FET for =<140Hz?

This would be for high voltage transformers from low voltage input.
 

Hi,

Relay and 140Hz ... I doubt you find some.

Klaus
 
  • Like
Reactions: Zak28

    Zak28

    Points: 2
    Helpful Answer Positive Rating
assuming a 50/50 duty cycle 140 Hz equals roughly a 3.5 millisecond on time. You are talking small reed-relay response times.

Reed relays are rated for very low voltages and currents.

So, I concur with Klaus.....extremely unlikely.
 
  • Like
Reactions: Zak28

    Zak28

    Points: 2
    Helpful Answer Positive Rating
The desired product is unclear to me.

AC-coil relays might be a bit funny operated at 140Hz but