T
treez
Guest
Hello The attached is a power supply involving eight current mode (CCM) bucks all in parallel, driving into the same load.
Its easy to get the Feedback loop bode plots (& calculate gain and phase margin and crossover) for one buck supplying into one load, but how is it done for eight in parallel?
Vin=28v
vout = 1v5
iout = 136.8A total
Each buck switches at 200khz and they are all interleave phased.
All their transconductance error amplifier outputs are connected together.
There is one output voltage feedback divider going into the "FB" pin of each LTC3892 Buck controller (FB pin is the error amplifier inverting input)
LTspice sim and pdf schem attached.
LTC3892 datasheet
http://cds.linear.com/docs/en/datasheet/38921fb.pdf
Its easy to get the Feedback loop bode plots (& calculate gain and phase margin and crossover) for one buck supplying into one load, but how is it done for eight in parallel?
Vin=28v
vout = 1v5
iout = 136.8A total
Each buck switches at 200khz and they are all interleave phased.
All their transconductance error amplifier outputs are connected together.
There is one output voltage feedback divider going into the "FB" pin of each LTC3892 Buck controller (FB pin is the error amplifier inverting input)
LTspice sim and pdf schem attached.
LTC3892 datasheet
http://cds.linear.com/docs/en/datasheet/38921fb.pdf