I wonder if I could use the UC3842 PWM controller in voltage-mode control in a two-switch flyback topology. This is the block diagram:
If I tie the VFB pin to ground I'll get a constant threshold of 1V at the CURRENT SENSE COMPARATOR noninverting input.
This way, by applying the output feedback voltage to CURRENT SENSE pin, I could (theoretically) control the PWM duty cycle.
The output feedback voltage should be designed using a voltage divider, to get an output of around 1V for the required output voltage.
Is it going to work this way? I have some concerns regarding loop compensation, as the output voltage (feedback) is read during transistor ON time, when the flyback diode is not conducting thus the output capacitor is discharged by the load.
- - - Updated - - -
Another variant it's to tie the CURRENT SENSE input to a fixed voltage (0.9V or something lower than the clamped 1V threshold) then to use the VFB input as ususal.
That way, when VFB is greater than 2.5V (ERROR AMP fixed threshold), the PWM pulse is turned off.
Any (other) ideas?
I wonder if I could use the UC3842 PWM controller in voltage-mode control in a two-switch flyback topology. This is the block diagram:
If I tie the VFB pin to ground I'll get a constant threshold of 1V at the CURRENT SENSE COMPARATOR noninverting input.
This way, by applying the output feedback voltage to CURRENT SENSE pin, I could (theoretically) control the PWM duty cycle.
The output feedback voltage should be designed using a voltage divider, to get an output of around 1V for the required output voltage.
Is it going to work this way? I have some concerns regarding loop compensation, as the output voltage (feedback) is read during transistor ON time, when the flyback diode is not conducting thus the output capacitor is discharged by the load.
- - - Updated - - -
Another variant it's to tie the CURRENT SENSE input to a fixed voltage (0.9V or something lower than the clamped 1V threshold) then to use the VFB input as ususal.
That way, when VFB is greater than 2.5V (ERROR AMP fixed threshold), the PWM pulse is turned off.