Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Analog amperemeter or Clamp amperemeter - which is true ?

Status
Not open for further replies.

anotherbrick

Full Member level 4
Full Member level 4
Joined
Jan 10, 2009
Messages
222
Helped
1
Reputation
2
Reaction score
1
Trophy points
1,298
Location
Istanbul , Turkey
Activity points
3,190
hello dear forum,

I have 28 KHz inverter which is driving LC circuit of a matching inductor in series with ultrasonic piezos

I want measure the current drawn from the lines

the analog amperemeter shows 5 amperes

( analog amperemeter is 10 amperes max )

where clamp amperemeter shows 4 amperes

( clamp meter is not true RMS - 20 Ampere range)

I wanna ask which is true ?

thank you
 

Hi,

Maybe both.

Maybe the one shos true RMS and the other average current.
What current do you need to know?

If you want to calculate the power dissipation of a resistor you need RMS.
If you want to calculate the power dissipation of a LED you need average current.

Klaus

Klaus
 
hello again ,

is it possible that the analog ammeter reads the vector sum of active and reactive currents ?

thank you

the schema of my circuit

**broken link removed**
 

The ammeter can not differentiate the currents as it has no voltage phase reference into it.
Frank

hello chuckey , sorry I ask again ( I am not good anymore at circuit theory - my EE diplom dates back to 1989 :) )

does the analog ammeter shows only active current that the circuit draws from lines ?

or is it the absolute value of vectoral sum of both ( active & reactive ) ?

why I ask this ?
I want calculate the power output of my circuit
thats why I want to clear this problem

thank you
 

It measures the absolute value. ie. the vectorial sum of real and reactive currents.

Frank

Please check the specifications of both ampere meters. I do not think any of them can measure current at 28 kHz.
The best way to know the real current is to use small resistors like 0.1 Ohm to 1 Ohm on the current-carrying lines, and an oscilloscope to read corresponding voltages at 28 kHz. A two-channel scope can read the phase between two current lines. But it may be difficult to prevent induction coupling between test lines to the scope. Use screened cables and be ready to experiment.
 