Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

constant current controller

Status
Not open for further replies.

Rujul Desai

Junior Member level 2
Junior Member level 2
Joined
Jan 22, 2015
Messages
22
Helped
1
Reputation
2
Reaction score
1
Trophy points
3
Location
Ahmedabad
Activity points
148
hi,

what is the meaning of inductor current critical mode?
 

it means that you have an smps where as soon as the inductor current falls to zero, the driving voltage is again forced across the inductor and the inductor current begins to build up again. So the inductor current falls to zero , but does not languish there.....in other words, the inductor current is triangular and not trapezoidal, and there are no "gaps" of zero inductor current, just "Points"
 
Hi.

Thanks for reply and help.
can you tell me how it work or use in constant current output circuit. ?
 
  • Like
Reactions: treez

    T

    Points: 2
    Helpful Answer Positive Rating
it can be used in constant current output, though is not particular to it......look at BCM Control IC's for led drivers....I think the UCC28600 is one....I also think linear.com do the LT3799

"cRITICAL CONDUCTION MODE" , WHICH YOU SPEAK OF, IS ALSO CALLED "boundary CONDUCTION MODE"
TO REGULATE CURRENT, YOU JUST CLOSE THE REGULATION LOOP AROUND A CURRENT SENSE RESISTOR. (sorry about caps)
 

Hi,

What is mean by Non isolated Buck LED Driver?

And what is isolated transformer?

Thanks
 