Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

centre taped and full bridge invertor

Status
Not open for further replies.

ismu

Full Member level 2
Full Member level 2
Joined
May 12, 2009
Messages
145
Helped
1
Reputation
2
Reaction score
1
Trophy points
1,298
Location
nil
Activity points
2,340
what is the differnce b/w centre taped and full bridge sine wave invertor ,which is cost effective & performance?
 

Class B transformer more expensive, but only one Vds/ Vce volt drop. Bridge, transformer cheaper, two transistor volt drops and four power devices plus added complexity. I would get quotes for the different sort of transformers and see what the price difference is, and then you can work out will this pay for the extra semiconductors.
Frank
 
  • Like
Reactions: ismu

    ismu

    Points: 2
    Helpful Answer Positive Rating
i have one more doubt : assume i have one bridge trmer , Vin=230 Vo=10V N1=230 turns and N2=10turns

here Vin/Vo=N1/N2 , my doubt is can i change N1=23 and N2=1 , bcs now also Vin/Vo=N1/N2 , and i can save copper price .
 

you cannot.
you would have several problems.
just check magnetic circuits' equations.
since the L will reduced drastically, you will definitely have short circuit problem. Furthermore the ransformer will not work near the knee of B-H curve etc
 
  • Like
Reactions: ismu

    ismu

    Points: 2
    Helpful Answer Positive Rating
can you share the all related equations?
 

The equations use symbols, and I unfortunately do not know how to type symbols here.
please refer to following books:
Dynamic Simulation of Electrical Machinery by: Chee-mun Ong pages:88-92.

Electric Machines Analysis and design by: Jim Cathey pages:142-150.

or any other book that discuss magnetic circuits.
 
  • Like
Reactions: ismu

    ismu

    Points: 2
    Helpful Answer Positive Rating
A non mathematical approach is that the limited primary inductance is a loss where current flows through it but does not get to the output. So suppose your working frequency is F HZ, then the primary inductance should have an impedance say, at least 10 times the reflected load impedance at F HZ. This is why 50 HZ transformers are wound with many turns of wire on a laminated iron core and high frequency transformers are wound with a much lower number of turns on a ferrite transformer. Radio frequency transformers may not have any cores at all.
Frank
 
  • Like
Reactions: ismu

    ismu

    Points: 2
    Helpful Answer Positive Rating
i have one more doubt : assume i have one bridge trmer , Vin=230 Vo=10V N1=230 turns and N2=10turns

here Vin/Vo=N1/N2 , my doubt is can i change N1=23 and N2=1 , bcs now also Vin/Vo=N1/N2 , and i can save copper price .
u can reduce production cast , use primary winding copper & 2ndry winding aluminum .its 200% reduce production cast .
 
  • Like
Reactions: ismu

    ismu

    Points: 2
    Helpful Answer Positive Rating
is there any disadvantags with aluminum windings?
 

it has about 60% of copper conductivity. so, higher resistance, so higher temperature. you may need to increase diameter of your wire.There is a aluminum oxide , I think it is not good heat transfer that means the heat can be imprison in your windings. I am not sure about second sentence.
 
  • Like
Reactions: ismu

    ismu

    Points: 2
    Helpful Answer Positive Rating