Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

triac is failing everytime..

Status
Not open for further replies.

deepakchikane

Full Member level 3
Full Member level 3
Joined
Jul 17, 2012
Messages
178
Helped
2
Reputation
4
Reaction score
2
Trophy points
1,298
Location
Mumbai, Maharashtra, India, India
Visit site
Activity points
2,623
Dear All,

here i am attaching the ckt diagram of my project..

please help me out for why :sad: is failing every time (without gate triggering)

plz plz plz
 

Attachments

  • IMAG0764.jpg
    IMAG0764.jpg
    788.8 KB · Views: 151

Which triac? T1 or T2 (or both)?

Without understanding your circuit's intended operation (what is the transformer for? What's it's ratio? What's the supply voltage/impedance?) a warning flag has popped up in my mind about your design exceeding the triac(s) di/dt and/or dV/dt limits. Series resistance (perhaps with some inductance) with whichever device is switching will undoubtedly help...
 

Which triac? T1 or T2 (or both)?

Without understanding your circuit's intended operation (what is the transformer for? What's it's ratio? What's the supply voltage/impedance?) a warning flag has popped up in my mind about your design exceeding the triac(s) di/dt and/or dV/dt limits. Series resistance (perhaps with some inductance) with whichever device is switching will undoubtedly help...

dear sir,
t1 & t2 ar the same..

transformer is of 230v to 16 v

i dont have other details


t1=btb24 by fairchild
 

I suspect what's happening is that on application of power, the resulting high dV/dt rate (across their MTx terminals) is triggering the triacs into conduction. Very large currents will then flow through the conducting triacs from the [low impedance] mains supply, undoubtedly killing them (quickly!)

Try adding a resistance (a 100W incandescent globe is a good indicator/indestructable load resistor) between the triacs, perhaps combined with 100 uH(ish)+ of inductance to limit the commutating currents/dI/dt. This will let you get a feel for the intended switching behaviour without destroying any more triacs. You can remove them later (or have a relay switch them out if they prove essential to surviving initial turn-on/mains transients) if you like.
 
I suspect what's happening is that on application of power, the resulting high dV/dt rate (across their MTx terminals) is triggering the triacs into conduction. Very large currents will then flow through the conducting triacs from the [low impedance] mains supply, undoubtedly killing them (quickly!)

Try adding a resistance (a 100W incandescent globe is a good indicator/indestructable load resistor) between the triacs, perhaps combined with 100 uH(ish)+ of inductance to limit the commutating currents/dI/dt. This will let you get a feel for the intended switching behaviour without destroying any more triacs. You can remove them later (or have a relay switch them out if they prove essential to surviving initial turn-on/mains transients) if you like.

hello sir,

i thnk you are into the right direction...

as i switched it with variacs it functions well...

but with the direct mcb it occurs problems..


do u have any solutions so that i can connect in proper way without harming triacs..

allready i failed 23 triacs from last weeks...

hoping for favourable reply as soon as possible
 

Put a .01 MF capacitor* inseries with a 100 ohm resistor across each triac. Now when the mains is switched on the very fast switching edge sends current down throuth the snubber network and not into the gate of a triac.
* make sure it is rated for 230 V AC and is a type X or Y - rated fro mains use.
Frank
 

Put a .01 MF capacitor* inseries with a 100 ohm resistor across each triac. Now when the mains is switched on the very fast switching edge sends current down throuth the snubber network and not into the gate of a triac.
* make sure it is rated for 230 V AC and is a type X or Y - rated fro mains use.
Frank

chuckey..

any mathematical calculation for snubber design for this..

as my resistor getting burnt
plzz
 

chuckey...

plz refer the circuit above posted....

my triac which is in ac path getting failed when i am giving some loads to the secondary side...

secondary side voltage is 220 volt with 12 amp..

in no load conditions,
it is not harming triac which is in path of ac
plz help me out fast
 

Hi , my guess is also a dv/dt failure. Do not let the gates floating . Put some RC protection circuit ( use a high power resistor not a 250mW one) ,connect the gates to cathodes and see if it still fails. If not , use some low impedance driver to drive T1 and T2. I really don't understand the use of T1. Witch is 220V side and witch 16V side on the transformer? Do you supply this circuit with 220V?
 

Xc = 10^6/ 2 x PI X .01 X 50 ~ 10^6/ PI ~ 300 k , So resistor current should be 240/300 mA ~ .8 mA, P100 = 100 X .64 micro watts or 6.4 mW . its good to see that the 100R resistor is soaking up power because the dissipation from the steady state AC is only 6.4 mW. However there should be no real heat, just a burst of power during the first few 1/2 cycles of the mains when powering or depowering. If its running hot, either the cap is too big in value, or its leaky, or there is something putting big transients down the AC line.
Frank
 
Xc = 10^6/ 2 x PI X .01 X 50 ~ 10^6/ PI ~ 300 k , So resistor current should be 240/300 mA ~ .8 mA, P100 = 100 X .64 micro watts or 6.4 mW . its good to see that the 100R resistor is soaking up power because the dissipation from the steady state AC is only 6.4 mW. However there should be no real heat, just a burst of power during the first few 1/2 cycles of the mains when powering or depowering. If its running hot, either the cap is too big in value, or its leaky, or there is something putting big transients down the AC line.
Frank

chuckey..
thanxx for the above mathematical expression..

do i use the same formula for the smps snubeer calculations...
& also things also in mind that when i am connecting two triac in a serias then there is not failures of triac anymore..
is this due the peak voltgae or dv/dv issues..??

- - - Updated - - -

Hi , my guess is also a dv/dt failure. Do not let the gates floating . Put some RC protection circuit ( use a high power resistor not a 250mW one) ,connect the gates to cathodes and see if it still fails. If not , use some low impedance driver to drive T1 and T2. I really don't understand the use of T1. Witch is 220V side and witch 16V side on the transformer? Do you supply this circuit with 220V?

T1 is used to short the primary of transformer..


the winding which is in series with the load is the 16 volt winding & triac is in parallel with the primary 230 vac windings..
 

At switch on, you have mains fed via the 16v winding to the load. if T1 is not already turned on, there will be a massive voltage generated by the 230V winding applied to T1 and T2. So the first thing to think about is to stop the full 230v being applied across the 16V winding. 16V rms ~ 46V p-p, put some 50V high power zeners across the 16v winding?, or some sort of delay circuit, to make sure T1 is ON before mains is applied. You could apply this technique to the secondary instead, this is what the T1 snubber is doing, the high voltage transient is being soaked up via the cap then putting real power into the resistor.
i am not sure what the circuit is mean't to do, either to switch the outgoing voltage to the load up by 16V, or to reduce it by the magic 16 V?
Frank
 

At switch on, you have mains fed via the 16v winding to the load. if T1 is not already turned on, there will be a massive voltage generated by the 230V winding applied to T1 and T2. So the first thing to think about is to stop the full 230v being applied across the 16V winding. 16V rms ~ 46V p-p, put some 50V high power zeners across the 16v winding?, or some sort of delay circuit, to make sure T1 is ON before mains is applied. You could apply this technique to the secondary instead, this is what the T1 snubber is doing, the high voltage transient is being soaked up via the cap then putting real power into the resistor.