Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
From the generator mode select two SINE wave signals as a input.
Put RMS voltage 115 and -115 with 50Hz frequency.
This create your 230V AC,50Hz sign wave input signal.
Then edit properties of the transformer component.
Set coupling factor as 0.0554.
to get exact 9V for center tap transformer.