I am also working on corrugated horn antenna and I am getting co-pol(gainx) +20 dB and cross pol(gainy) -18 dB. But, problem is that I am getting peak in cross pol at boresight. Can you help me in finding reason for the same?
hey as i m interested in to test the cross and copolar level when corrugated antenna is verticaly polarised and horizontally polarized both.....
and how did u know it is lineraly polarized in X direction.....
Hi
I did not see this post till now.
As long as there is a large difference between co-pol and cross-pol, it should be fine. It is common to find a small peak at boresight for the cross-pol also. It depends on your antenna design and we cannot make any guesses without talking specifics.
Now, I am getting very good response. co polarization is 21 dB and cross polarization is now -62 dB
- - - Updated - - -
just by giving modes in reverse order. means, if you have define 1st mode in x direction, then replace it by giving it in y direction and 2nd one in the x direction in place of y direction. k?
Hi
I did not see this post till now.
As long as there is a large difference between co-pol and cross-pol, it should be fine. It is common to find a small peak at boresight for the cross-pol also. It depends on your antenna design and we cannot make any guesses without talking specifics.
Now, I am getting very good response. co polarization is 21 dB and cross polarization is now -62 dB
- - - Updated - - -
just by giving modes in reverse order. means, if you have define 1st mode in x direction, then replace it by giving it in y direction and 2nd one in the x direction in place of y direction. k?
Looks good to me.
One simple way is to rotate your input setup by 90 deg about the Z axis.
Then your modes will now also change their alignment and you will get the opposite linear polarization. (i.e. E aligned along Y)[/QUOTE/]
we design inx-y plane then how to change input setup by 90 abt z?