Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Altium Clearance Rule question, newbie user > easy fix maybe!

Status
Not open for further replies.

drx

Newbie level 1
Newbie level 1
Joined
Jan 22, 2013
Messages
1
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,294
Hello all, I am creating a Pcb with Altium Dxp for the first time.
Simple issue: The default clearance rule on the board specifies 8mil. See here:
1.jpg

This is fine for everything on the board except for some nets which will carry higher voltage, for which I would like to set the clearance to 16mil. I have created the following rule. The nets are listed in the 'First Object...Query' box:
2.jpg

This new rule is set with higher priority than the first rule:
3.jpg

In my current understanding of Altium's rule system, I thought this would require any copper track attached to one of those nets have 16mil of clearance to any other object (with different net). However, the clearances for these tracks still seems to be 8mil:
4.jpg

In the upper right of the editor window, the 'TESTOUT-' track is passing by at less than 10mil from the other pad... and checking the 'Applicable Binary rules' for these two objects, only the default clearance rule shows up.
I'm new at this, so hopefully it's just something easy I missed... Any ideas??
Thanks in advance!!
 

The best way to do this is to create a Net class and add the nets to the class. Go to Design, Classes. Right click Net Classes and select new. Give it a name and select the nets you want in the class. Now go to your design rules, create a new clearance and give it a name like HiCurrent or whatever you want. Select Net Class and and select the net class you created. Make your spacing rule 16mils. Creating classes help you to keep track much easier than selecting individual nets. Also makes it easy to add or remove nets within the class
 
Hi,

Use OR instead of AND while passing query.

Creating net class and passing the query for net class is the best way.

Regards
Anil
 