Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Current transformer with up to 10A DC in the primary...will it saturate?

Status
Not open for further replies.
T

treez

Guest
Newbie level 1
Hello

I have a 50KHz sinusoidal current which I must detect. The current is full wave rectified, so its actually pulsating DC half-sines.
The current is sinusoidal, but may be an average of 1A, or 2A, or 3A, or 4A…………..to 10A.

I must detect whether it’s a 1A, or a 2A , or a 3A……to 10A, that’s flowing………so I don’t need great accuracy, just to depict which one of these current levels it is that’s flowing.

Here is a picture of the 10A average rectified current that I must detect…..
https://i46.tinypic.com/2mxpjdg.jpg


….Do you think this is best done with a current sense transformer?

…..The DC level for the 10A one, is, exactly that ..10 Amps, and that seems an awful lot to put through a current transformer…transformers don’t like DC, surely.

I was wondering of the B82801B0205A100 (1:100) current sense transformer is up to this job?…..

B82801B series C.T. datasheet:-
https://www.epcos.com/inf/85/ds/b82801b.pdf

….the frequency range for almost all off-the-shelf current sense transformers is either 20KHz-50KHz or 50KHz-1MHz.
…..this makes it awkward for me because I am right on the boundary…i.e. 50KHz.

Also, the equation on page 5 of the B82801B series datasheet has a “duty cycle” parameter in it……..though my waveform, (shown above) is just a continuous train of half-sines…….so I don’t know what to put in for the “duty cycle” parameter?

So anyway, do you think the B82801B0205A100 C.T. will be OK for this job, and not saturate?
 

Could you just pass the current through a sense resistor? Then you can just use a voltage comparator(s). What voltages are you dealing with?
 
  • Like
Reactions: treez

    T

    Points: 2
    Helpful Answer Positive Rating
Do you have the possibility to put the CT in the AC input to the rectifier?

It will saturate as the V*s product is just 10uVs with 80uH primary inductance. 10uVs into 80uH results in 125mA.

If you don't have access to the AC current, and you need isolation, you may use a gapped core transformer with very low primary inductance that does not saturate under peak current condition. Of course, this will introduce some minor voltage drop. To get the AC current component you need to use a low pass filter to integrate the output wave form. Instead of a gapped core, you may use a very low permeability ring core (iron powder).

Complete other option is to use a hall type sensor with or without feedback.
 
  • Like
Reactions: treez

    T

    Points: 2
    Helpful Answer Positive Rating
Because of the saturation problem of a transformer I would suggest measuring the voltage across a shunt resistor in series with the circuit or, if you need isolation, a Hall-effect current sensor.
 
  • Like
Reactions: treez

    T

    Points: 2
    Helpful Answer Positive Rating
thanks, thoughthe hall sensors always need an expensive mini magnet in there aswell, which makes it pricey, and pricey to assemble because the magnet needs mounting
 

thanks, thoughthe hall sensors always need an expensive mini magnet in there aswell, which makes it pricey, and pricey to assemble because the magnet needs mounting
No. The magnetic field the Hall sensor detects is generated by the current flow. You don't need any external magnet.
 
  • Like
Reactions: treez

    T

    Points: 2
    Helpful Answer Positive Rating
Hi,
If you want to use CT, you should put it before the rectifier stage.
regards ani
 
  • Like
Reactions: treez