Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Testing RF waveguide detector

Status
Not open for further replies.

MobiNaz

Full Member level 3
Full Member level 3
Joined
Aug 11, 2010
Messages
163
Helped
5
Reputation
10
Reaction score
4
Trophy points
1,298
Location
SYDNEY
Activity points
2,432
Hello All,

I am testing a RF waveguide detector (Hughes 47321H-2100 )fed by a RF power generated by a sweep oscillator at around 40 GHz (sweep 0.01sec). I am then measuring the output voltage by a digital multimeter. The output is not steady initially but keeps on increasing. The output does stops at some values but isflunctuating. Why is this happening? How do I determine that a certain value is actually the output voltage?


Thanks in advance.
 

because the frequency is sweeping, including a big portion of time when the output retraces, and the output power is therfore varying.
 

First problem I think is to use a DVM on fluctuating voltage. Use an oscilloscope, and use a variable attenuator before your detector! Typical microwave sweep oscillators deliver +13...+15 dBm output, which can kill your detector in seconds. It starts by heating it- this looks to you as a variation. Sweep oscillators also need adjustments and do not generate too stable power over time.
First you can test your detector when the signal generator is set to CW at some frequency. I would advise to start with a power meter, and adjust generator settings for a stable power. Apply no more than -10 dBm to the detector, otherwise you damage it.
Then if the power output is stable, replace the power meter with the attenuator and detector, with a power to the detector < -10 dBm. Then you can use the swept frequency, and on the oscilloscope you can see output voltage detected across the swept band. Then connect the sweep horizontal output from the sweep generator to oscilloscope X channel, and you can see how the sweeper and detector behave together over the swept frequency band.
 