Charging 100 uF from the high side driver to 0.5CV^2 in the RC time must produce excessive current with low ESR and excessive V drop on high side. Try a soft start with an L and PWM
 
Charging 100 uF from the high side driver to 0.5CV^2 in the RC time must produce excessive current with low ESR and excessive V drop on high side. Try a soft start with an L and PWM
I have removed the 100uf capacitor I still get 7.8Vac at my high side outputs how but 11.2Vac at my low sides
 
Charging 100 uF from the high side driver to 0.5CV^2 in the RC time must produce excessive current with low ESR and excessive V drop on high side. Try a soft start with an L and PWM
I have removed the capacitor n still get low voltage at my highside driver outputs. Could u redraw my schematics may b my connection of the high side is wrong but low side seems OK . highside is at spwm frequency of 16kHz,low side is at 50Hz
 